Arc flash assessment, hazard study and short circuit fault current calculation  
  Arc Flash, Short Circuit Analysis
  Expert Advice for
Arc Flash Analysis
 
   Home Page
 
  SHORT CIRCUITS:
   Online Calc
   Reference Data
 
  ARC FLASH:
   AFA v5.0 [new]
   AFA v4.1
   AFA v3.2
   DC Calculator
   DC Software
   IEEE 1584 Calc
   Program Review
   Video Tutorials
 
  SERVICES:
   Label Printing
   Advertising
 
   Surplus Stock
   Info / FAQ
   Examples
 
   Blog
   Contact Us
   Testimonials
   Terms of Use
   News & Links
   Site Map

COMPANY PROFILE:

By providing on-line and PC based software for Short Circuit and Arc Flash Hazard Analysis, ARCAD INC. helps create a safer working environment for individuals who service electrical systems. ARCAD service includes resources and convenient tools that allow facility managers to perform short circuit incident energy, arc flash protection boundary, level of personal protection equipment (PPE) calculations, and to create customized arc flash warning labels, thus reducing the cost of obtaining compliance with OSHA, NFPA70E, and the new Canadian CSA Z462 standards.

Arc Flash and Short Circuit Analysis

IEEE 1584 and NFPA 70E based Arc-Flash-Analytic v 5.0 tool for arc flash hazard analysis (PC version for Windows 9X, XP, Vista, Windows 7) has been released.

Click the image below to launch a video tutorial

CSA Z462 IEEE 1584 NFPA 70E Arc Flash Analysis Video

Step by step tutorial demonstrating arc flash analysis using Arc Flash Analytic 4.1 Low Voltage Circuit Breaker Equations Mode.

Please visit the links below for additional product information:
Arc Flash Software, Arc Flash Labels Buying Arc Flash Hazard Analysis & Label Making Software
Electric Arc Flash Analysis Software Installation Arc Flash Hazard Software Registration
Arc Flash Analysis Label Making Software Features Arc Flash Program - Fuse Equations Tutorial
Electric Arc Flash Study using IEEE 1584 Empirical Model Incident Energy Arc Flash Exposure for Live Line Work
Arc flash software for DC power systems

BONUS - Free Short Circuit Software included

  • Build comprehensive one-line diagrams
  • Save a system and open a previously saved system
  • Print out input, output values and one-line diagrams
  • Calculate minimum and maximum available short-circuit currents

Purchase Arc Flash Analytic v5.0 software and receive 30-day use of the ArcAd Online Short Circuit Calculator for free


More Information

More information

Benefits of Using Arc Flash Analytic v5.0:

  • Calculator-style interface makes complex calculations easy to understand.
  • Design safer power systems while insuring compliance with NEC 110.16, OSHA, NFPA 70E, IEEE 1584 and CSA Z462 standards.
  • Avoid potential fines, lost productivity, and increased insurance and litigation costs.
  • Save time by generating arc flash warning labels in electronic PDF, JPG and BMP formats.
  • Evaluate threshold incident energy for a second degree burn at the arc flash boundary.
  • Save input data, calculation results for future reference or printing.
  • Perform analysis using metric (mm, Joules ) or imperial units (inches, calories ).
  • Calculate arc blast explosion pressure and arc TNT equivalent.
  • Create arc flash and shock hazard warning labels in English, French or Spanish.

arc flash software

Related Information: Arc Flash Analytic 5.0 Product Page

Spend $400 or more on ARCAD stocked products and get Arc Flash Analytic 4.1 software FREE

arc flash software exclusive coupon

Must mention ESAVINGS promotional code in comments field upon checkout or by email to sales@arcadvisor.com

ARCAD Online Short Circuit Calculator

Determining available short circuit fault currents is one of the most important aspects of designing power distribution systems. Short circuits and their effects must be considered in selecting electrical equipment, circuit protection devices, and in carrying out arc flash analysis. The short circuit calculator presented on this web-site is offered to satisfy the need for a convenient, comprehensive method of calculating single and three phase distribution system short circuit fault currents. It is intended for radial and looped low voltage (LV) and high voltage (HV) circuits. The calculator allows users to quickly and easily obtain accurate potential short circuit currents at each node (bus) in a power distribution system.

Arc Flash Online Calculator

We have developed an easy-to-use and comprehensive online tool for calculating arc incident energy, flash protection boundary and risk category required by NEC when work is to be performed on or near the energized equipment. The calculator takes equipment configuration, gap between electrodes, grounding type, short circuit fault current value and system voltage on input, determines arcing fault current, calculates incident energy, arc flash protection boundary, hazard / risk level at the potential point of fault and creates detailed warning label [more...].

What makes our short circuit calculator different?

ArcAd's online short circuit calculator features input data analysis and hard coded error propagation rules. This ensures that the resulting fault current values are no more precise than justified by the accuracy of input data [ more... ]. This is a very important but widely ignored issue.

The calculator has unparalleled ability to accurately handle motor and generator contributions. Many programs and procedures of this type do not properly account for motor loads as they simply have the user add the motor contribution to the utility source KVA. Some programs make short circuit fault current assumptions based on transformer size etc. This inadvertently distorts short circuit fault current values and blurbs the safety margin. The calculator allows motors and generators to be placed anywhere in the network. The contribution from each motor and the utility source is vectorally added at every point at which they intersect. This provides an extremely accurate analysis of the maximum short circuit MVA any node can be subject to.

By performing short circuit MVA analysis for positive, negative, and zero sequences, symmetrical three phase and unsymmetrical phase to ground, phase to phase, double phase to ground fault currents can be resolved.

The calculator procedure is based on the MVA method for solving industrial power system short circuits. Each component of the power system is assigned an MVA short circuit rating. For example, the short circuit MVA contribution of the motor is equal to its own MVA base divided by its own per unit impedance. The cable or bus short circuit MVA rating is equal to (kV)2 / Z, where kV is the cable line voltage and Z is cable impedance.

To use the short circuit calculator:

Briefly review the examples and frequently asked questions to see the procedure in action, and to learn the resource capabilities.

Create an account if you don't already have one, and log onto the page where you can add components one by one to build up a radial electrical distribution system. The components can be a power source, transformers, bus ducts, cables, motors and generators, or "special" components whereby the user can define his own X and R values for a non-standard device. Short circuit MVA values contributed both by source and the system equipment are calculated for each portion of the system.

Your account gives you the advantage of saving the entered system diagram and the ability experiment with other configurations. This is practical for systems with multiple scenarios of interconnections where the system goes through ongoing changes over a period of time. You may continue your analysis without having to re-enter your data from the beginning.

More Frequently Asked Questions:

Creative Safety Supply

Creative Safety Supply
Arc Flash Software
arc flash software
toro banner
Label Printing Services
Arc Flash Label
Printing Services

CHECK THESE OUT
arc flash clothing

Sign up for our Email Newsletter
Write us at: